Carbon Reduction Plan
Grove Hospitals Radiology Ltd
At Grove Hospitals Radiology, we are dedicated to environmental responsibility and sustainability. Our goal is to achieve Net Zero emissions by 2040, aligning with government targets and global climate initiatives. Through strategic carbon reduction efforts, we are actively working towards minimising our environmental impact while maintaining the highest standards of diagnostic imaging services.
Baseline Emissions Footprint
Baseline emissions represent the starting point for measuring our progress in carbon reduction. These emissions serve as a benchmark against which future reductions are tracked.
Baseline Year: 2024
Additional details on emissions calculations:
Grove Hospitals Radiology had not previously assessed emissions before 2024. Emissions have been calculated using UK Government GHG Conversion Factors 2024 and operational data from our Bluewater facility.
Baseline Year Emissions (2024)
| Emissions Category | Scope | Description | Emissions (tCO2e) |
|---|---|---|---|
| Scope 1 | Direct emissions | Company vehicles (2 diesel vehicles, 10,000 miles/year total) | 3.03 |
| Scope 2 | Energy indirect | Electricity consumption (90,038 kWh/year: MRI scanner 51,840 kWh, heating 12,480 kWh, cooling 16,848 kWh, ultrasound 576 kWh, PACS 2,765 kWh, lighting 922 kWh, other 4,608 kWh) | 17.38 |
| Scope 3 | Other indirect | Staff commuting (55,296 km/year), waste disposal (3,840 kg/year), supply chain | 9.78 |
Total Emissions: 30.19 tCO2e
Emissions Breakdown by Percentage:
• Scope 1 (Direct): 10.0%
• Scope 2 (Energy Indirect): 57.6%
• Scope 3 (Other Indirect): 32.4%
Key Emission Sources:
MRI Scanner (Siemens 1.5T Aera): 51,840 kWh/year (10.00 tCO2e) – largest single source
Cooling and Ventilation: 16,848 kWh/year (3.25 tCO2e)
Electric Heating: 12,480 kWh/year (2.41 tCO2e)
Staff Commuting: 55,296 km/year (7.20 tCO2e)
Company Vehicles: 10,000 miles/year (3.03 tCO2e)
Current Emissions Reporting
Reporting Year: 2025
| Emissions Category | Scope | Description | Emissions (tCO2e) |
|---|---|---|---|
| Scope 1 | Direct emissions | Company vehicles (reduced mileage through route optimization) | 2.27 |
| Scope 2 | Energy indirect | Electricity consumption (67,529 kWh/year after LED lighting, improved heating controls) | 13.03 |
| Scope 3 | Other indirect | Staff commuting (reduced through remote work), waste disposal, supply chain | 7.34 |
Total Emissions: 22.64 tCO2e
Reduction Achieved: 7.55 tCO2e (25% reduction from 2024 baseline)
Through initial reduction strategies, we have already achieved a 25% reduction in emissions since 2024, demonstrating our commitment to Net Zero by 2040.
Carbon Reduction Projects
Completed Carbon Reduction Initiatives
Since establishing our baseline in 2024, Grove Hospitals Radiology has implemented several initiatives to reduce our carbon footprint:
Energy Efficiency:
• LED Lighting Transition: Replaced all conventional lighting with LED bulbs in mobile units, reducing lighting electricity usage from 922 kWh to 830 kWh per year (10% reduction, saving 0.02 tCO2e).
• Heating Controls: Implemented programmable thermostats and improved insulation, reducing heating electricity usage by 10% (saving 1.25 tCO2e).
Waste Management:
• Implemented a comprehensive waste management policy, minimising landfill waste and increasing recycling of non-clinical materials.
• Reduced general waste by 15% through improved segregation and recycling (saving 0.01 tCO2e).
Transport:
• Promoted remote work options for administrative and reporting radiologists, reducing commuting emissions by 10% (saving 0.72 tCO2e).
• Optimized vehicle routes for equipment servicing, reducing company vehicle mileage by 25% (saving 0.76 tCO2e).
Resource Efficiency:
• Adopted a paper reduction policy, cutting paper consumption by 10% through digital patient records and electronic reporting.
Total carbon emission reduction achieved: 7.55 tCO2e (25% overall emissions reduction compared to 2024).
Future Carbon Reduction Projects
Transport and Fleet Management (Target: 2.0 tCO2e reduction by 2030)
• Electric Vehicle Transition: Replace 2 diesel company vehicles with electric vehicles by 2027, eliminating 2.27 tCO2e of Scope 1 emissions.
• Staff Commuting Incentives: Introduce cycle-to-work scheme and public transport subsidies, targeting additional 15% reduction in commuting emissions (1.08 tCO2e).
Renewable Energy (Target: 3.5 tCO2e reduction by 2030)
• Solar Panel Installation: Install solar panels on mobile unit roofs or explore renewable energy purchasing agreements to generate 20% of electricity needs (18,000 kWh/year), reducing emissions by 3.47 tCO2e.
• Green Electricity Tariff: Switch to 100% renewable electricity supplier by 2028, eliminating all Scope 2 emissions (13.03 tCO2e).
Equipment Efficiency (Target: 2.0 tCO2e reduction by 2030)
• MRI Scanner Optimization: Implement advanced power management systems to reduce MRI standby power consumption by 30% (saving 0.67 tCO2e).
• Cooling System Upgrade: Install energy-efficient air conditioning with smart controls, reducing cooling electricity usage by 20% (saving 0.65 tCO2e).
• Equipment Replacement: Prioritize energy-efficient models during equipment replacement cycles.
• Energy Audit: Conduct comprehensive energy audit of mobile units to identify further efficiency improvements by Q2 2026.
Waste Reduction (Target: 0.05 tCO2e reduction by 2030)
• Expand recycling programmes to include all non-clinical waste, targeting 50% waste reduction.
• Implement a circular economy approach for medical equipment, prioritizing refurbishment and resale.
• Reduce single-use plastics in patient care areas.
Supply Chain Engagement (Target: 1.5 tCO2e reduction by 2030)
• Work with suppliers (Ergea, Simplex, SJ Electrical Services) to understand and reduce their carbon footprint.
• Prioritize suppliers with strong environmental credentials and Net Zero commitments.
• Request carbon data from all major suppliers and include carbon performance in procurement decisions.
Digital Transformation
• Expand teleradiology services to reduce patient travel for follow-up consultations.
• Implement cloud-based PACS solutions to reduce on-site server energy consumption.
These initiatives will further drive our sustainability goals and help us achieve Net Zero by 2040.
Emissions Reduction Targets
Grove Hospitals Radiology is committed to the following carbon reduction targets:
| Target Year | Reduction Target | Emissions (tCO2e) | Key Milestones |
|---|---|---|---|
| 2024 | Baseline | 30.19 | Initial emissions assessment completed |
| 2025 | 25% reduction | 22.64 | LED lighting, waste management, remote work, vehicle optimization |
| 2030 | 50% reduction | 15.09 | Electric vehicle fleet, solar panels/renewable energy, energy-efficient equipment, staff commuting incentives |
| 2035 | 75% reduction | 7.55 | Full renewable electricity, circular economy practices, supply chain decarbonization |
| 2040 | Net Zero | 0.00 | Carbon offsetting for remaining emissions, full decarbonization |
Projected Annual Reductions:
• 2025–2030: Average 1.51 tCO2e reduction per year
• 2030–2035: Average 1.51 tCO2e reduction per year
• 2035–2040: Average 1.51 tCO2e reduction per year
Detailed Emissions Breakdown
Scope 1: Direct Emissions (3.03 tCO2e in 2024)
Company Vehicles:
• 2 diesel vehicles used for equipment maintenance and site visits
• Total annual mileage: 10,000 miles (16,090 km)
• Fuel consumption: 1,126 litres diesel
• Emissions: 3.03 tCO2e
Reduction Strategy: Replace with electric vehicles by 2027 (eliminating 3.03 tCO2e)
Scope 2: Energy Indirect Emissions (17.38 tCO2e in 2024)
Electricity Consumption: 90,038 kWh/year
| Equipment/System | Annual kWh | Emissions (tCO2e) | % of Total |
|---|---|---|---|
| MRI Scanner (Siemens 1.5T Aera) | 51,840 | 10.00 | 57.6% |
| Cooling/Ventilation | 16,848 | 3.25 | 18.7% |
| Electric Heating | 12,480 | 2.41 | 13.9% |
| Other Equipment | 4,608 | 0.89 | 5.1% |
| PACS Workstations | 2,765 | 0.53 | 3.1% |
| LED Lighting | 922 | 0.18 | 1.0% |
| Ultrasound Equipment | 576 | 0.11 | 0.6% |
| Total | 90,038 | 17.38 | 100% |
Reduction Strategies:
• Solar panels/renewable energy purchasing (targeting 20% reduction by 2030)
• Switch to 100% renewable electricity tariff (eliminating all Scope 2 emissions by 2028)
• MRI power management systems (30% standby reduction)
• Energy-efficient cooling systems (20% reduction)
Scope 3: Other Indirect Emissions (9.78 tCO2e in 2024)
Staff Commuting: 7.20 tCO2e
• 4 staff members on site per day
• 288 operating days per year
• Average commute: 24 km each way (48 km return)
• Total distance: 55,296 km/year
• Mode split: 70% car (38,707 km), 30% public transport (16,589 km)
Waste Disposal: 0.08 tCO2e
• Clinical waste: 2,400 kg/year
• General waste: 1,440 kg/year
• Total: 3,840 kg/year
Supply Chain: 2.50 tCO2e (estimated)
• Equipment servicing and maintenance
• Supplies delivery
• Medical consumables
Reduction Strategies:
• Remote work expansion (targeting 25% total reduction in commuting by 2030)
• Cycle-to-work scheme and public transport subsidies
• Waste reduction and recycling programmes (targeting 50% waste reduction)
• Supplier engagement on carbon reduction
Governance and Accountability
Carbon Reduction Oversight:
• The Board of Directors (Dr. Davoud Khodatars, Dr. Desmond Owusu, Dr. Asad Tamimi) has overall responsibility for carbon reduction strategy.
• The Registered Manager (Amanda Graham) oversees implementation of carbon reduction initiatives.
• Annual carbon audits will be conducted to track progress against targets.
• Quarterly reviews of energy consumption and emissions performance.
Reporting and Transparency:
• Annual carbon emissions reports will be published on the Grove Hospitals Radiology website.
• Progress updates will be provided to NHS partners and stakeholders.
• Carbon reduction performance will be included in annual business reviews.
• Compliance with PPN 06/21 requirements for NHS supply chain.
Investment Commitment:
• Dedicated annual budget for carbon reduction initiatives
• Prioritization of energy-efficient equipment in capital expenditure decisions
• Green financing options to be explored for major investments (solar panels, electric vehicles)
Methodology and Assumptions
Emissions Calculation Methodology:
• UK Government GHG Conversion Factors 2024
• Scope 1 and Scope 2 reported in accordance with SECR requirements
• Scope 3 assessed under the Corporate Value Chain (Scope 3) Standard
• Operational control approach used for organizational boundary
Key Assumptions:
• MRI scanner power consumption: 35 kW scanning, 10 kW standby
• MRI operating hours: 8 hours/day, 6 days/week, 48 weeks/year
• 50% scanning time, 50% standby time
• UK grid electricity factor: 0.193 kg CO2e/kWh (2024)
• Diesel vehicle fuel consumption: 7 litres/100 km
• Staff commuting: 70% car, 30% public transport
Data Quality:
• Scope 1: High (actual fuel consumption records)
• Scope 2: High (actual electricity meter readings from Bluewater)
• Scope 3: Medium (estimated based on operational data and industry averages)
Declaration and Sign-Off
This Carbon Reduction Plan has been prepared in compliance with PPN 06/21 and aligns with the GHG Reporting Protocol Corporate Standard.
Scope 1 and Scope 2 emissions have been reported in accordance with SECR requirements, and Scope 3 emissions have been assessed under the Corporate Value Chain (Scope 3) Standard.
This plan has been reviewed and approved by the Grove Hospitals Radiology Ltd Board of Directors.
Dr. Asad Tamimi
Director and Consultant Radiologist
Grove Hospitals Radiology Ltd
Date: 1st December 2025
Download Our Full Carbon Reduction Plan
At Grove Hospitals Radiology, we believe in full transparency and accountability when it comes to our sustainability efforts. This document represents our detailed Carbon Reduction Plan, including our current emissions, reduction strategies, and future commitments towards achieving Net Zero by 2040.
Contact: info@groveradiology.co.uk
Website: www.groveradiology.com
Grove Hospitals Radiology Ltd
Company Number: 15621894
Registered Office: 277-279 Chiswick High Road, London, W4 4PU
END OF DOCUMENT